Description
Amending Chapters 1.2 (Residential Code) and 1.8 (Fire Code) of Title VIII of the Los Altos Hills Municipal Code Which Adopts and Amends by Reference Provisions of the 2019 California Building Standards Code and Local Code Amendments
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
315.8.9 Collection containers. Containers used to collect or store lithium batteries shall <br />be noncombustible and shall not have an individual capacity exceeding 30 gallons (113.6 <br />L), or be approved for transportation in accordance with the Department of Transportation <br />(DOT). <br />315.8.10 Storage configuration. Lithium batteries shall be considered a high -hazard <br />commodity in accordance with Chapter 32 and where applicable, lithium battery storage <br />shall comply with Chapter 32 in addition to Section 315.8. <br />R. Section 316.7 is added to read as follows: <br />Section 316.7 Roof guardrails at interior courts. <br />Roof openings into interior courts that are bounded on all sides by building walls shall be <br />protected with guardrails. The top of the guardrail shall not be less than 42 inches in height <br />above the adjacent roof surface that can be walked on. Intermediate rails shall be designed <br />and spaced such that a 12 -inch diameter sphere cannot pass through. <br />Exception: <br />Where the roof opening is greater than 600 square feet in area. <br />S. Section 503.1.1 is amended to read as follows: <br />503.1.1 Buildings and facilities. Approved fire apparatus access roads shall be provided <br />for every facility, building or portion of a building hereafter constructed or moved into or <br />within the jurisdiction. The fire apparatus access road shall comply with the requirements <br />for this section and shall extend to within 150 feet (45 720 mm) of all portions of the facility <br />and all portions of the exterior walls of the first story. of the building as measured by an <br />approved route around the exterior of the building or facility. <br />Exceptions: <br />1. In other than R-3 or U occupancies, when the building is equipped throughout with an <br />approved automatic sprinkler system, installed in accordance with Section 903.3.1.1 <br />the dimension may be increased to a maximum of 300 feet when approved by the fire <br />code official. <br />2. When there are not more than two Group R-3 or accessory Group U occupancies, the <br />dimension may be increased to a maximum of 200 feet. <br />3. When apparatus roads cannot be installed because of topography, waterways, <br />nonnegotiable grades or other similar conditions, an approved alternative means of fire <br />protection shall be provided. <br />T. Section 503.2.2 is amended to read as follows: <br />Ordinance 588 Page 5 <br />