My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PC 09-22
LOSALTOSHILLS
>
Planning Commission
>
Planning Commission Resolutions
>
2022
>
PC 09-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2022 9:18:55 AM
Creation date
6/7/2022 9:18:11 AM
Metadata
Fields
Template:
Resolutions
Number
PC 09-22
Date
05/12/2022
Description
Approving a Site Development Permit for the Construction of a New Two-Story Residence at 25240 Cantata Way
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Dwelling Units (ADUs), provided that all of the following are met: a) The unit meets the <br />definition of an Accessory Dwelling Unit as defined in the Government Code Section <br />65852.2. b) The existing primary residence does not have automatic fire sprinklers. c) The <br />detached ADU does not exceed 1,200 square feet in size. d) The unit is on the same lot as <br />the primary residence. e) The unit meets all access and water supply requirements of Chapter <br />5 and Appendix B and C of the 2019 California Fire Code. Provide a note on the building <br />plan set cover sheet that sprinkler system will be installed for both residence and ADU. <br />51. Required Fire Flow: The minimum require fireflow for this project is 1125 Gallons Per <br />Minute (GPM) at 20 psi residual pressure. This fireflow assumes installation of automatic <br />fire sprinklers per CFC [903.3.1.3]. <br />52. Private Fire Protection System: Residential fire protection systems shall comply with Fire <br />Department Standards W-1 and manufacturer's requirements. Fire protection water systems <br />shall be permitted, installed and approved by the Fire Prevention Office. The wharf hydrant <br />shall be accessible at all times. Tank systems providing both the domestic supply and supply <br />to the sprinkler system and/or hydrant may require cross contamination protection. Check <br />with the local Building Department for specific requirements related to protection of the <br />domestic supply. Water tanks other than steel construction shall not be located 20 feet from <br />any structure. Volume of fire protection water supply shall be based on NFPA 1142. Make <br />a note on coversheet that water tanks and wharf hydrant will be installed during building <br />permit. <br />53. Fire Hydrant Systems Required: Where a portion of the facility or building hereafter <br />constructed or moved into or within the jurisdiction is more than 400 feet from a hydrant on <br />a fire apparatus access road, as measured by an approved route around the exterior of the <br />facility or building, onsite fire hydrants and mains shall be provided where required by the <br />fire code official. Exception: For Group R-3 and Group U occupancies equipped throughout <br />with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1, <br />903.3.1.2 or 903.3.1.3, the distance requirement shall be not more than 600 feet. [CFC, <br />Section 507.5.1]. The residence exceeds the 600' maximum distance from the hydrant to the <br />farthest exterior corner of the structure. Make a note on cover sheet that private fire <br />protection system will be installed. Wharf hydrant location noted on sheet A0.7. <br />54. Fire Department (Engine) Driveway Turnaround Required: Dead-end fire apparatus access <br />roads in excess of 150 feet in length shall be provided with an approved area for turning <br />around fire apparatus. Provide an approved fire department engine driveway turnaround <br />with a minimum radius f 36 feet outside and 23 feet inside. Maximum grade in any <br />direction shall be 5%. Installations shall conform with Fire Department Standard Details <br />and Specifications D-1. [CFC Section 503.2.5]. No parking shall occur within the <br />turnaround. On sheet A1.0, underground septic tank proposed within the turnaround. Show <br />on plans that there will be traffic rated 75,000 lbs capacity. <br />55. Fire Apparatus (Engine) Access Driveway Required: (As Noted on Sheet C-1) An access <br />driveway shall be provided having an all-weather surface of either asphalt, concrete or other <br />engineered surface capable of supporting 75,000 pounds and approved by a civil engineer. It <br />shall have a minimum unobstructed width of 12 feet, vertical clearance of 13 feet 6 inches, <br />Resolution PC 09-22 Page 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.