Adopts and Amends by Reference the 2013 California Building Standards Code and Local Amendments and the Reorganization and Renumbering of Existing Statutes in Title VIII
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 3405.6.1 <br /> PERFORMANCE CRITERIA FOR CBC LEVEL SEISMIC FORCES <br /> OCCUPANCY CATEGORY PERFORMANCE LEVEL PERFORMANCE LEVEL <br /> (BASED ON CBC TABLE FOR USE WITH ASCE 41 FOR USE WITH ASCE 41 <br /> 1604.5) BSE-1 EARTHQUAKE BSE-2 EARTHQUAKE <br /> HAZARD LEVEL HAZARD LEVEL <br /> I Life Safety(LS) Collapse Prevention(CP) <br /> II Life Safety(LS) Collapse Prevention(CP) <br /> III Note(a) Note (a) <br /> IV Immediate Occupancy(IO) Immediate Occupancy(IO) <br /> (a) Acceptance criteria for Occupancy Category III shall be taken as 80 percent of the <br /> acceptance criteria specified for Occupancy Category II performance levels, but need <br /> not be less than the acceptance criteria specified for Occupancy Category IV <br /> performance levels. <br /> 3405.6.2 Compliance with reduced CBC level seismic forces. Where seismic <br /> evaluation and design is permitted to meet reduced California Building Code seismic <br /> force levels, the procedures used shall be in accordance with one of the following: <br /> (1) The California Building Code using 75 percent of the prescribed forces. <br /> Values of R, Do, and Cd used for analysis shall be as specified in Section <br /> 3405.6.1 Item 1. <br /> (2) Structures or portions of structures that comply with the requirements of the <br /> applicable chapter in Chapter A of the 2012 International Existing Building <br /> Code as specified in Items (a) through (e) below shall be deemed to comply <br /> with this section. <br /> (a) The seismic evaluation and design of unreinforced masonry bearing wall <br /> buildings in Occupancy Category I or II are permitted to be based on the <br /> procedures specified in Chapter Al. <br /> (b) Seismic evaluation and design of the wall anchorage system in reinforced <br /> concrete.and reinforced masonry wall buildings with flexible diaphragms <br /> in Occupancy Category I or II are permitted to be based on the procedures <br /> specified in Chapter A2. <br /> (c) Seismic evaluation and design of cripple walls and sill plate anchorage in <br /> residential buildings of light-frame wood construction in Occupancy <br /> Category I or II are permitted to be based on the ,procedures specified in <br /> Chapter A3. <br /> Ordinance 558 Page 6 <br />