Planning Commission <br /> ti Lands of Gorman&Cheng(lot 22) <br /> March 11, 1998 <br /> Page 3 <br /> -_ would make the residence highly visible from Stonebrook Drive and from other homes to <br /> the west. <br /> Exterior colors have not yet been chosen, although the plans indicate that the roofing <br /> would be dark gray. Staff will review proposed colors for conformance with the Town's <br /> adopted color board,prior to acceptance of plans for building plan check. <br /> Square Footage <br /> The applicants are proposing to use a recycled material called "Rastra" for the walls of <br /> the house. A brochure about the material has been included for the Commission's <br /> information. Rastra is thicker than most walls, providing better energy efficiency. The <br /> Zoning Ordinance states that everything within the exterior walls is floor area. Since the <br /> Rastra material combined with the stucco finish is 11 inches thick, the applicants have <br /> requested that they be allowed to calculate the floor area from the centerline of the <br /> exterior walls rather than including the entire wall (see Attachment 9). A typical wall <br /> thickness for standard construction would be about six inches. The proposed floor area is <br /> at the maximum allowed for the property based on slope density calculations. If the <br /> entire wall thickness is counted, the total "floor area" would exceed the allowable limit. <br /> This is an unusual circumstance and one which staff has not encountered before. The <br /> thicker walls would add to the massing of the structure and the Code requires floor area to <br /> be counted from the exterior walls. If the Commission determines that the entire wall <br /> thickness should be counted as floor area, condition #1 should be modified to require <br /> revisions to the floor plans to keep the project within the allowable floor area of 5,943 <br /> square feet. <br /> Neighborhood and Architectural Committee Concerns <br /> The architectural review committee for the Stonebrook Subdivision(J. Lohr Properties) is <br /> concerned about the proposed exterior materials, the second story massing and the low <br /> roof pitch of the proposed residence. Jerry Lohr's letter of February 24, 1998 points out <br /> that the exterior siding is entirely stucco, and that many of the other homes in the <br /> subdivision have used stone, brick or wood in place of or to break up stucco. Also, the <br /> two other homes at the entrance to the subdivision have all stucco exteriors. The <br /> Planning Commission has expressed concern about the number of houses with stucco <br /> siding in the Stonebrook Subdivision in the past. The Design Guidelines state that a <br /> mixture of materials can create interest and details, and that texture and well designed <br /> detail added to wall surfaces helps minimize the impact of large wall surfaces. Staff has <br /> included wording in condition #1 requiring the applicants to add stone or brick as an <br /> accent to the exterior of the house. If the Planning Commission decides that this is not <br /> necessary, this language should be deleted from the condition. <br /> While there are no other homes with metal roofs in the subdivision, there are residences <br /> in the Town that have used this material. There are no code provisions prohibiting the <br /> use of metal roofing. The Commission has been concerned about the reflectivity of metal <br /> roofing with other applications, and staff has included wording in condition #2 requiring <br /> the material to have as non-reflective finishing as possible. Condition #8 requires the <br /> color of the roofing to be dark enough that it has 40% or less reflectivity. <br /> As mentioned in Jerry Lohr's letter, the low roof pitch does place more emphasis on the <br /> walls of the house. The height of the walls is greater since the roof does not comprise <br /> much of the overall height of the structure. Suggestions were given to reduce or break up <br /> the wall in front of the garage and the two-story stairwell. The project architect believes <br /> that the low roof pitch minimizes the overall massing of the house. The architect's <br />