- 04-14-98 16:42 21 4Ud 2b"( "'bU4 Hnsnutiz/zention Lr UPJ; <br /> Harari Memo <br /> 4/14/98 Paga,2 <br /> Landscape Plan . <br /> (Plans have revised by landscape architect and not available to me at this time) <br /> Floor Plans, shts. A2,A3 <br /> 1. Most of the major rooms and hallways on all levels have been reduced in size and the <br /> main stair has been turned 90, degrees for a more efficient plan of reduced floor area. <br /> 2. Some upstairs walls were re-aligned to eliminate some flat roof areas. <br /> • <br /> 3. The overall depth of the Master Bdrm, and Bath areas on the second floor was reduced <br /> from 22'-0"to 19'-0" so that the roof ridge above would be lowered to match the adjacent <br /> ridge over Hall 4. This also reduces the exterior depth and mass of the whole front <br /> portion of the house as seen in the revised exterior elevations. <br /> 4. These sheets in the original submittal have not been revised for this submittal. The <br /> changes are primarily internal and a revised floor area worksheet, showing new floor and <br /> development areas is attached. The effects of these floor plan changes on the exterior of <br /> the building are indicated on the, revised exterior elevations and sections. <br /> Building Sections, shts. A4, A5 " <br /> 1. Sections have been revised to show new floor elevations per town datum and to match <br /> revised grading plan. <br /> 2. Roof ridge heights and overall heights have been changed. Overall heights from the <br /> highest ridges to typical finished grade are lowered by 2'-0". <br /> 3. Roof pitches are reduced from 5:12 to 4-1/2:12 to reduce overall roof height. <br /> 4. First floor joists are shown flush with the tops of foundation walls instead of on top of the <br /> walls. This allows the overall building height to be reduced by 1'-0". Also, the first floor- <br /> to-pad height is shown as 2'-6". <br /> Front Elevation (entry), sht. A6 <br /> 1. The drawing has been revised to show the roof, floor and opening heights and sizes <br /> more accurately. The overall height is 2'-0" lower than what was indicated on the <br /> previous plan. . <br /> 2. The front door entry columns,.roof and dormer have been reduced in size, height, <br /> complexity and ornament. The door and window openings are smaller, the gabled roof <br /> plate has been lowered to match the plate height of rest of the house and the gabled roof] <br /> pitch has been lowered from 10:12 to 9:12. <br /> 3. The spacing between the corbels shown at the roof eave has been increased to reduce <br /> the number of corbels. <br /> 4. The typical roof pitch is now indicated as 4-1/2:12 instead of 5:12. <br />