Loading...
HomeMy WebLinkAboutItem 3.2TOWN OF LOS ALTOS HILLS August 12, 2004 Staff Report to the Plannine Commission RE: CONDITIONAL DEVELOPMENT PERMIT FOR A NEW RESIDENCE; LANDS OF CHO; 13389 WILDCREST DRIVE; #111-04-ZP-SD-GD-CDP. FROM: Debbie Pedro, Associate Planner APPROVED BY: Carl Cahill, Planning Director C.(.� That the Planning Commission: Approve the requested Conditional Development Permit, subject to the recommended conditions and findings of approval in Attachments 1 and 2. BACKGROUND The subject property is a hillside lot located on the south side of Wildcrest Drive. An existing two-story residence with an attached garage is situated on the upper, southern portion of the lot with steep slopes directly above and below the building pad. Surrounding uses include single-family homes on adjacent parcels to the east, west, and south and across Wildcrest Drive to the north. The applicant is proposing to demolish the existing building on the site and construct a new two-story residence with an attached garage. As required by Section 10-1.1104 of the Zoning Code, this application for a new residence has been forwarded to the Planning Commission for review and approval. A Conditional Development Permit is required any time a proposed project is located on a property with a Lot Unit Factor (LUF) of 0.50 or less. Pursuant to Section 10-1.1107(3) of the Zoning Ordinance, the Planning Commission, in reviewing a Conditional Development Permit application, determines whether the proposed development meet the objectives and standards of the Town by considering evidence in support of four necessary findings. The applicant has prepared Findings for approval of the Conditional Development Permit for the Commission's review (Attachment 2). In addition, the Zoning and Site Development sections of the Municipal Code are used to evaluate new residences including building siting, floor and development area limitations, grading, drainage, height, setbacks, visibility, and parking requirements. Staff Report to the Planning Commission Lands of Cho 13389 Wildcrest Drive August 12, 2004 Page 2 of 12 DISCUSSION Site Data: Gross Lot Area: 1.006 acres Net Lot Area: 0.981 acres Average Slope: 35.0% Lot Unit Factor: 0.455 Floor Area and Development Area: Area (sq. ft.) Maximum Existing Proposed Increase Remaining Development 6,650 7,000 6,621 -379 29 Floor 4,550 2,770 4,468 1,698 82 Site and Architecture The applicant is requesting approval of a Conditional Development Permit for a 4,468 sq. ft. two-story residence with an attached garage. Constrained by steep topography, the proposed home is sited in approximately the same location as the existing structure. The first floor of the new residence has 2,745 sq. ft. of floor area and contains a foyer, living room, family room, dining room, kitchen, guest bedroom, utility rooms and a three -car garage. The second floor has 1,723 sq. ft. of living area and includes three bedrooms, three bathrooms, a study and a playroom. The proposed building meets the setback, height, floor area and development area requirements established in Title 10, Zoning and Site Development, of the Los Altos Bills Municipal Code. The maximum building height on a vertical plane and the maximum height of the building from the lowest point to the highest point is 26'l I". Proposed materials on the house include cement plaster finish exterior, vinyl windows, wrought iron railings, and concrete flat roof tiles. Several skylights are proposed on the house and requirements to reduce light emission from skylights are included. (Condition of Approval #10) Driveway & Parking Access to the property is currently provided via two existing driveways. The first driveway comes off of a 30' wide ingress/egress easement along the east side of the property which serves three (3) other residences on Wildcrest Drive. The second driveway, constructed by the previous owner without prior Town approval, is accessed from Wildcrest Drive along the north property line. The applicant is proposing to remove Staff Report to the Planning Commission Lands of Cho 13389 Wildcrest Drive August 12, 2004 Page 3 of 12 the unpermitted driveway and restore the area with natural vegetation. The garage at the north end of the house provides three (3) parking spaces with standard dimensions of 10' x 20'. One (1) additional outdoor parking space is located directly north of the garage outside of the required setbacks. Outdoor Lighting Ten (10) exterior wall lights are proposed around the house and manufacturer's specifications of the lighting fixtures are included on the site plan. Staff has included condition #7 requiring the light fixtures to be down shielded, low wattage, and the glass covers on the light fixtures be frosted or opaque so that the source of the lighting is not directly visible from off-site. Trees & Landscaping There are a numerous trees and dense shrubbery on and around the property. Several trees, including an acacia, pepper, bay, plums, and three small oaks (less than 12" trunk diameter), are proposed to be removed as part of the site development proposal. All heritage oak trees on the property will be preserved. The location and type of trees to be removed are detailed on the site plan (Sheet A2). To ensure that all significant trees will be protected throughout the construction period, staff has included condition of approval #4 requiring that the trees within the vicinity of the construction be fenced with chainlink for protection. In addition, the applicant is proposing to remove approximately 1,260 sq. ft. of asphalt driveway north of the house and restore the area with landscaping. A landscape screening plan will be required after final framing of the proposed residence (Condition #2). Furthermore, any landscaping required for screening or erosion control will be required to be planted prior to final inspection, and a maintenance deposit to ensure viability of plantings will be collected prior to final inspection. Geotechnical Review The Town's geotechnical consultant reviewed the plans and noted site constraints including expansive earth materials, existing artificial fill materials, and potential landslide hazards on the property. The project consultant has evaluated the site constraints and has provided geotechnical design recommendations that satisfactorily address the geotechnical project design concerns. Consequently, the Town's geotechnical consultant has prepared conditions of approval for the project as designed. These requirements are included as conditions #13a and #13b. Staff Report to the Planning Commission Lands of Cho 13389 Wildcrest Drive August 12, 2004 Page 4 of 12 Grading and Drainage Total proposed grading quantities include 700 cubic yards of cut (for the foundation, fire truck turnout, and retaining walls at the rear of the house) and 100 cubic yards of fill (for the driveway). The Engineering Department has reviewed the proposed grading and concluded that it is not in conformance with the Town's grading policy. Specifically, retaining walls of up to 6' are proposed for the driveway, the fire truck turnout and at the back of the house. In addition, up to 10' of fill (approximately 250 sq. ft. in area ) is proposed for the back up area in front of the garage at elevation contour 336. Per the Town's grading policy, the maximum cut and fill levels for a retaining wall is 4' and 3' respectively. The grading policy allows the Planning Commission the discretion to approve grading levels beyond standard requirements when the individual site dictates the need to deviate from the criteria. The subject property is constrained by site topography, specifically the steep slopes north and south of the building pad . The applicants and their engineer have considered several site designs. The City Engineer has reviewed the plans concluded that the steep topography dictates some grading beyond policy guidelines. If the Planning Commission approves the project as proposed, the Engineering Department recommends conditions of approval which have been included in attachment #1. Pursuant to Section 10-2.503, Drainage Facilities Standards, of the Municipal Code, the Engineering Department has reviewed and determined that the proposed drainage design complies with Town requirements. Storm water runoff generated from the new development will be collected and carried to two 48" perforated pipes north of the new residence where it will be retained and dissipated on-site. The applicant's engineer has provided a storm flow analysis and calculations showing that the drainage improvements will mitigate impacts of the site development and the quantity and flow rate of onsite surface runoff will not increase beyond the pre -development level. Fire Department Review The Santa Clara County Fire Department inspected the property and determined that the site is inaccessible to fire apparatus due to the existing topographical conditions. As a result, the Fire Department is requiring the construction of a 20'W x 55'L fire truck turnout within the ingress egress easement leading to the residence. Furthermore, the flow capacity of the nearest water mains and fire hydrant will not be adequate for a home of the proposed size and the applicant would be required to provide a fire sprinkler system throughout all portions of the building to meet the Fire Department's requirements. (Conditions of Approval #24 and #25) Staff Report to the Planning Commission Lands of Cho 13389 Wildcres[Drr e August 12, 2004 Page 5 of 12 Committee Review The Pathways Committee recommends a pathway in -lieu fee which is included as condition #23. The Environmental Design Committee has requested that an existing 14" oak tree along the driveway be preserved and that skylights be subject to standard conditions of approval. These comments have been incorporated into recommended conditions of approval #4 and #10. Conditional Development Permit Pursuant to Section 10-1.1107(3) of the Town's Zoning Code, prior to granting a Site Development permit on a substandard lot, the Planning Commission must make four specific findings to determine that the proposed development meets the objectives and standards of the Town and the new construction is appropriate for the site and the surrounding neighborhood. The site for the proposed development is adequate in size, shape and topography to accommodate the proposed intensity of development. The property is currently developed with a single family home constructed in 1958. The applicant is proposing to replace the existing two-story house with a new two-story house in approximately the same location, minimizing disturbances to the natural slopes. The floor area and development areas of the proposed home is below the MDA and MFA allowed for the site and the proposed design meets the height, setback, and parking requirements of the Town. The size and design of the proposed structures create a proper balance, unity and harmonious appearance in relation to the size, shape and topography of the site and in relation to the surrounding neighborhood. Due to topographical constraints, the proposed development is modest in size and will cover approximately 15% of the one acre property. The size and design of the new house within the Town's setback, height, and MDA/NMA requirements and is in keeping with other homes in the surrounding neighborhood. The rural character of the site has been preserved as much as feasible by minimizing vegetation and tree removal, excessive and unsightly grading and alteration of natural land forms. The proposed new residence is sited over the existing building pad which will minimize excessive grading and alteration of natural land forms on the property. A number of trees will need to be removed around the vicinity of the building site to accommodate the new development However, no heritage oak trees will be affected. In Staff Report to the Planning Conunission Lands of Cho 13389 Wildcre tDrive August 12, 2004 Page 6 of 12 addition, the existing secondary driveway will be removed and the area replanted with natural vegetation. The restored area will help screen the home from neighbor's views and help preserve the rural character of the site. The proposed development is in compliance with all regulations and polices set forth in the Site Development Ordinance. The proposed development meets the setback, height, floor area and development area requirements established in the Town's Zoning and Site Development Code. However, due to the difficulty of the site terrain and the steep contours, some minor exceptions to the Town's grading policy are required for the retaining walls, driveway backup and fire truck turnout areas. CEOA STATUS The project is categorically exempt under Class 1 of the State CEQA Guidelines ATTACHMENTS 1. Recommended conditions of approval 2. Findings for Approval of the Conditional Development Permit prepared by the applicants dated July 29, 2004 3. Site Map 4. Worksheets #1 and #2 5. Recommendations from Santa Clara County Fire Department dated July 26, 2004 6. Recommendations from Cotton, Shires & Associates dated July 23, 2004 7. Recommendations from Environmental Design Committee dated May 27, 2004 8. Development plans: site, topographic, grading & drainage, floor, elevation, section, roof, and lighting plans cc: Tom Cho and Stephanie Wu 13389 Wildcrest Drive Los Altos Hills, CA 94024 Scott Hoffman Mission Engineers, Inc. 355 Reed St. Santa Clara, CA 95050 Mike Ma P.O. Box 6365 San Mateo, CA 94403 Staff Report to the Planning Commission Lands of Cho 13389 W ildcrest Drive August 12, 2004 Page 7 of 12 ATTACHMENT 1 RECOMMENDED CONDITIONS FOR A CONDITIONAL DEVELOPMENT PERMIT FOR A NEW RESIDENCE LANDS OF CHO, 13389 WILDCREST DRIVE File # 111-04-ZP-SD-GD A. PLANNING DEPARTMENT: 1. No other modifications to the approved plans are allowed except as otherwise first reviewed and approved by the Planning Director or the Planning Commission, depending on the scope of the changes. 2. Subsequent to final framing, a landscape screening and erosion control plan shall be reviewed by the Site Development Committee. Particular attention shall be given to plantings that will be adequate to break up the view of the new residence from surrounding properties and streets. All landscaping required for screening purposes or for erosion control (as determined by the City Engineer) must be installed prior to final inspection. 3. A landscape maintenance deposit (or certificate of deposit) in the amount of $5,000 shall be posted prior to final inspection. An inspection of the landscape to ensure adequate establishment and maintenance shall be made two years after the installation. The deposit will be released at that time if the plantings remain viable. 4. Prior to beginning any grading operation, all significant trees, including an existing 14" oak tree north of the driveway, are to be fenced at the drip line. The fencing shall be of a material and structure (chain-link) to clearly delineate the drip line. Town staff must inspect the fencing and the trees to be fenced prior to commencement of grading. The property owner shall call for said inspection at least three days in advance of the inspection. The fence must remain throughout the course of construction. No storage of equipment, vehicles or debris shall be allowed within the drip lines of these trees. Existing perimeter plantings shall be fenced and retained throughout the entire construction period. 5. At the time of foundation inspection for the new residence and prior to final inspection, the location and elevation of the new residence shall be Staff Report an the Planning Commission Lands of Cho 13389 Wildcresl Drive August 12, 2004 Page 8 of 12 certified in writing by a registered civil engineer or licensed land surveyor as being in/at the approved location and elevation shown on the approved Site Development plan. At the time of framing inspection for the new residence, the height of each building shall be similarly certified as being at the height shown on the approved Site Development plan. 6. Pursuant to Section 10-1.501.b.2 of the Zoning Code, the roof eaves of the building may extend into the side and rear yard setbacks by 12". 7. The existing secondary driveway along the north property line with access off of Wildrest Drive shall be removed prior to final inspection. 8. Outdoor lighting is approved as shown on the approved site plans. No lighting may be placed within setbacks except two entry or driveway lights. Lighting shall be down shielded, low wattage, shall not encroach or reflect on adjacent properties, and the source of the lighting shall not be visible from off the site. The glass on the proposed light fixtures (Hapsburg KLT9061 and KLT-9062) shall have frosted or opaque covers. Any additional outdoor lighting shall be approved by the Planning Department prior to installation. 9. Fire retardant roofing (Class A) is required for all new construction. 10. Skylights shall be designed and constructed to reduce emitted light (tinted or colored glass, or other material). No lighting may be placed within skylight wells. 11. Any new fencing or gates shall require review and approval by the Planning Department prior to installation. 12. All properties must pay School District fees to either the Los Altos School District or the Palo Alto Unified School Districtl, as applicable, before receiving their building permit from Los Altos Hills. The applicant must take a copy of Worksheet #2 to school district offices (both the elementary and high school offices in the Los Altos School District), pay the appropriate fees and provide the Town with a copy of their receipts. B. ENGINEERING DEPARTMENT: 13. As recommended by Cotton, Shires & Associates, Inc., in their report dated July 23, 2004, the applicant shall comply with the following: Staff Report to the Planning Commission Lands of Cho 13389 Wildcrest Drive August 12, 2004 Page 9 of 12 a. Geotechnical Plan Review — The applicant's geotechnical consultant should evaluate the results of the project geologic report and verify that described site fill conditions are satisfactorily addressed by recommended project geotechnical design criteria. The consultant should review and approve all geotechnical aspects of the project building and grading plans (i.e., site preparation and grading, site drainage improvements and design parameters for foundations, retaining walls and driveway) to ensure that their recommendations have been properly incorporated. The consultant should verify that appropriate locations have been selected for water energy dissipaters to minimize the potential for adverse slope stability impacts. The results of the plan review should be summarized by the geotechnical consultant in a letter and submitted to the Town Engineer for review and approval prior to acceptance of documents for building permit plan -check. b. Geotechnical Field Inspection — The geotechnical consultant shall inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections should include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations and retaining walls prior to the placement of steel and concrete. The results of these inspections and the as -built conditions of the project shall be described by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to final (granting of occupancy) project approval. For further details on the above geotechnical requirements, please refer to the letter from Cotton, Shires & Associates, Inc., dated July 23, 2004. 14. Peak discharge at 13389 Wildcrest Drive, as a result of Site Development Permit 111-04, shall not exceed the existing pre -development peak discharge value of the property. Detention storage must be incorporated into the project to reduce the predicted peak discharge to the pre - development value. Provide the data and peak discharge hydrologic model(s) utilized, as well as, the calculations of the peak discharge value Staff Report to the Planning Commission Lands of Cho 13389 Wildcrest Drive August 12, 2004 Page 10 of 12 prior and post development. Determine the design peak runoff rate for a 10 -year return period storm and provide detention storage design plans to reduce the predicted peak discharge to the pre -development value. All documentation, calculations, inflow hydrograph, and detention storage design (2 plan copies) shall be submitted for review and approval to the satisfaction of the City Engineer prior to acceptance of plans for building plan check. Prior to final inspection, a letter shall be submitted from the project engineer stating that the detention storage design improvements were installed as shown on the approved plans and in accordance with their recommendations. 15. Any, and all, changes to the approved grading and drainage plan shall be submitted as revisions from the project engineer and shall first be approved by the Town Engineering Department. No grading shall take place during the grading moratorium (November 1 to April 1) except with prior approval from the City Engineer. No grading shall take place within ten feet of any property line except to allow for the construction of the driveway access. 16. All public utility services serving this property shall be placed underground. 17. At the time of foundation inspection for the new residence and prior to final inspection, the location and elevation of the new residence shall be certified in writing by a registered civil engineer or licensed land surveyor as being in/at the approved location and elevation shown on the approved Site Development plan. At the time of framing inspection for the new residence, the height of each building shall be similarly certified as being at the height shown on the approved Site Development plan. 18. Two copies of an erosion and sediment control plan shall be submitted for review and approval by the Engineering Department prior to acceptance of plans for building plan check. The contractor and the property owner shall comply with all appropriate requirements of the Town's NPDES permit relative to grading and erosion/sediment control. The first 100 feet of the driveway shall be rocked during construction and all cut and fill slopes shall be protected from erosion. All areas on the site that have the native soil disturbed shall be protected for erosion control during the rainy season and shall be replanted prior to final inspection. Staff Report to the Planning Commission Lands of Cho 13389 W ildcresl Drive August 12, 2004 Page I1 of 12 19. Two copies of a grading and construction operation plan shall be submitted by the property owner for review and approval. by the City Engineer and Planning Director prior to acceptance of plans for building plan check. The grading/construction operation plan shall address truck traffic issues regarding dust, noise, and vehicular and pedestrian traffic safety on Wildcrest Drive and surrounding roadways, storage of construction materials, placement of sanitary facilities, parking for construction vehicles, clean-up area, and parking for construction personnel. A debris box (trash dumpster) shall be placed on site for collection of construction debris. Arrangements must be made with the Los Altos Garbage Company for the debris box, since they have a franchise with the Town and no other hauler is allowed within the Town limits. 20. The property owner shall inform the Town of any damage and shall repair any damage caused by the construction of the project to pathways, private driveways, and public and private roadways, prior to final inspection and release of occupancy permits and shall provide the Town with photographs of the existing conditions of the roadways and pathways prior to acceptance of plans for building plan check. 21. The driveway shall be required to be fully constructed and to be roughened where the pathway intersects, to the satisfaction of the City Engineer, prior to final inspection. 22. The property owner shall submit three sets of a sanitary sewer plan for review and approval by the Public Works Department prior to submittal of building plan check. An encroachment permit shall be required by the Town's Public Works Department for all work proposed within the public right of way prior to start work. 23. The property owner shall pay a pathway fee of $45.00 per linear foot of the average width of the property prior to acceptance of plans for building plan check. C. FIRE DEPARTMENT: 24. The property owner shall provide an automatic residential fire sprinkler system approved by the Santa Clara County Fire Department throughout all portions of the new residence. Three copies of plans prepared by a State of California licensed fire protection contractor shall be submitted to the Staff Report to the Planning Commission Lands of Cho 13389 Wildcrest Drive August 12, 2004 Page 12 of 12 Planning Department and approved by the Fire Department, prior to acceptance of plans for building plan check, and the sprinklers shall be inspected and approved by the Fire Department, prior to final inspection. 25. A 20' wide x 55' long fire truck turnout shall be constructed within the ingress egress easement north of the driveway entrance. The fire truck turnout shall be inspected and approved by the Fire Department prior to final inspection. 26. The property address shall be placed on the main residence so that it is clearly visible and legible from the street or road fronting the property. The address numbers shall be a minimum of four inches high and shall contrast with the background color. CONDITION NUMBERS 13a, 14, 18, 19, 20, 22, 23 AND 24 SHALL BE COMPLETED AND SIGNED OFF BY THE PLANNING DIRECTOR AND THE CITY ENGINEER PRIOR TO ACCEPTANCE OF CONSTRUCTION PLANS FOR PLAN CHECK BY THE BUILDING DEPARTMENT. Project approval may be appealed if done so in writing within 23 days of the date of this notice. The building permit cannot be issued until the appeal period has lapsed. The applicant may submit construction plans to the Building Department after September 4, 2004, provided the applicant has completed all conditions of approval required prior to acceptance of plans for building plan check. Upon completion of the construction, a final inspection shall be required to be set with the Planning and Engineering Departments two weeks prior to final building inspection approval. NOTE: The Site Development permit is valid for one year from the approval date (until August 12, 2005). All required building permits must be obtained within that year and work on items not requiring a building permit shall be commenced within one year and completed within two years. ATTACHMENT D -RECEIVED 9JgUpL 2 9 2004 Conditional Development Permit for 13389 Wilderest Dr. Los Altos Hills, FO<NN OP L0S ALTOS HILLS Findings The findings for a Conditional Development Permit are as followings: 1. The site for the proposed development is adequate in size, shape and topography to accommodate the proposed intensity of development, including all structures, yards, open spaces, parking, landscaping, walls and fences and other such features as may he require by this chapter. We had done our very best to comply with all the Zoning and Site Development codes of the Town of Los Altos Hills for our proposed new 2 story home. Based on the topography of the property, this property has a LUF of 0.455, MFA of 4550 and MDA of 6650. Our proposed home is within all of these ordinances. And, the roof height is also within the allowable height of 27 feet. We also had provided 4 parking spaces as required. Due to the difficulty of the site terrain and the steep contours, some grading is required for the retaining walls and the drive way cut out per the Santa Clara County Fire Department. The un -permitted long driveway in front of the house installed by the previous owner will be removed and replaced with nature vegetation. 2. The size and design of the proposed structures create a proper balance, unity and harmonious appearance in relation to the size, shape and topography of the site and in relation to the surrounding neighborhood. The houses in the WildcresUWildflower private road area are newer and larger homes. There are only a small number of the older and smaller homes remain in the neighborhood. The proposed home is clearly modest in size and height in the area. This proposed home would subtly integrate with the surrounding neighborhood and become harmonious with its natural setting. This will definitely improve the overall property values of the neighborhood. 3. The rural character of the site has been preserved as much as feasible by minimizing vegetation and tree removal, excessive and unsightly grading and alteration of natural land forms. We have kept the disruption of the natural terrain and vegetation to an absolute minimum. The landscaping in the front of the house will remain as is. All dry weeds and dead plants in the property will be clear for fire safety. The un -permitted driveway in front of the house installed by the previous owner will be restored and replaced with nature vegetation. 4. The proposed development is in compliance with all regulations and polices set forth in the Site Development Ordinance. We have substantially complied with the Site Development Ordinance. Due to the difficulty of the site terrain, it is unavoidable for us to put up retaining walls that are taller than the guidelines. It is a requirement by the City Engineer to have adequate turning radius in front of the garage. For this matter we are asking for the planning commission for approval. All other developments of this Site are in compliance with all regulations and policies of the Town. i �0 CL 29 W V CL I4 75 r4 U� O� N ATTACHMENT: O N V 021 a. O s Go L > dQ3'19ob b N � \ I .1 so �E cel O� e raa �M 4 _ p G Filr Zrl y � i s Lh 201pf o- All m �) Lh P�v�OOL A ollib _ a �.i y IG'10 -EI I/ A' 'LZ /. /s Our/ 1 G S p lirsf g � c �(s oNNvsi vfoi AN�. 6' G LI C r4i 6ry' tt. 1 tq Ml • If'... eJ on- 12 04 05:43. Mi. Ma fG' 549-2027 p.11 ATTACHMENT ' f ,Eo,VV OF Los ALTOSHII.LS 26379 Premoat Road • Lris Phos 7 ttf� NG DEPART:��NT� �n 1-7222 ° PA7: (G50) 541-3160 " bTtrORKSHEI:T #xl CALCTJL.AT O„,T OF AVERAG AREA 'D MAXIMUM X,ML rT FACTOR M FLOOR AREA . . MAXD0JM DEVELOP y1EN-T ARh- I. CALCULATION OF AVERkCF.. SLOPE A, CONTOUR LENGTSI `NiTIHN 2v''E"f' ARI -'A OF L.OT (An) LENGTH (WCHES) II (I?QCHES) TOTAL _ 7 . feet Convert inches to feet (mliLiiply by rv?ap scale) _ (L) _ _ cZ. B. AVERAGE SLOPE �%JIT7�,T.-'1 NET AREA OF LOT — --- �” Anacreage of S = (0.0023) (I) (L) 1 = c Sfeet tour i_merval L -total length of lot nearest.001 ip. ( contows 7n fee An f L,_ �_— S'(7%_lam)_ 2. CALCULATION OF LOT_vTT FACTOR fLLT') nearest .001 LI 1;7 LUP } If the average slop �s i ,e di ffi1 �.0°/ tbe LUF "or the for - 7 ta] to h het �? } If,h LUP is cq' al to or ]es i ? O.Sq c nu vn11 need a 4,o'ndttional Dc oFivay i M'i<e an appointmen,: will! the Plan, ng D.rector for rvrihcr t .9ornafto /t(/ `D_ �1 Pace 1 a'2 Rar 12 04 09:44. Mi.= i9a_. 649-2927 P.12 WORKSHEET #1, '- (continued) i 3. CALCULATION OF MAXI'-`'ruTM DEVELOPNIENT AREA 1vIDA A. for S equal to or less thin 10% square feet" NIDA = (LUF) (15,000) _ 1 B. for Sgreater than 10%u and less than 309% square feet* MDA = (LUF) 115,000 - 375(S -"0A = C. for S equal to or greater than 30% square feet* MDA = (LUT)' (7,500) =-. �.— i 6R er P 1 R i ?._ I C �, C `�C� a- i.5a2 C-) 'ss Lb use 7,500 square feet for * If the NIDA is less than 7,70C square feet (and the LUF is greater than 0.50), your MDA 4. CALCULATION OF MAXIMUb°+FZ.00R AREA (MFA A. for S equal to or less than 10% square feet** MFA = (LUF) (6,000) = B. for S greater than 10%n and less than 30% square feet** MFA = ¢UF) [6,000 - SG(5 - 10A _ C. for S equal to or greater than 30% square feet** MFA = (I SA') (5,000) r1rr\ ** If the . A is less thaw 5,000 sycare feet (and he LUF is greater than OSO) use 5,000 square feet for your MFA. NOTE: The MDA and MFA are maximums allowed by the Town Municipal Code. The City Council or the Planning Commission may furiher limit development area or floor area due to site specific constraints or site visibility (see "Site 1)6elopment Policy Statement"). gp. 7 Past 2 of 2 oxv en aim 'Fr 12 04 09: 46a f1 " = Ma f6 ' 649-2927 TOWN OF LOS ALTOS HILLz5 PLANNING DEPAR'T'MENT 26379 Fremont Road ^ Los Altos Bills, Califomia 94022 • (650) 941-7222 • FAX (650) 941-3160 WORKSHEET #2 EXISTING AND PROPOSED DEVELOPMENT AREA AND FLOOR AREA • TURN IN VVITB YOUR APPLICATION PROPERTY OWNER'S PROPERTY ADDRESS CALCULATEDBY c tt � AATEd ,;%' 1. DEVELOPMENT AREA (SQUARE FOOTAGE) A. House and Garage (,from Par[ 3. A.) B. Decking (Fg-aT) C. Driveway and Parking (Measured 100' alone centerline) D. Patios and Walkways( oa�-tslof-) E. Tennis Court , F. Pool and Decking G. Accessory Buildings(from Part B) H. Any other coverag�AG UrJCf QAp) TOTALS Existing Proposed Total (Addiboas;➢•edons) -2-2 li�� ilk ✓ c� ��Tf Zo ✓ Maximum Development Area Allowed - MDA (from Worksheet #1) fC✓��sJ-+ 2. TOTALIMPERVIOUS SUWACE Existing Proposed Total (SQLARE FOOTAGE) � TOTALS 3. FLOOR AREA (SQUARE FOOTAGE) A. House and Garage a. 1st Floor ` 2! b. 2ndFloor c. Atticand Basement d. Garage B. Accessory Buildings a 1st Floor b. 2nd Floor C. Attic and Basement TOTALS<�777 '' Existing Proposed Total (AdditionslDeieHoas) Maximum Fiocr Area Allowed - MFA (from Worksheet #1) TOWN USE ONLY I C13ECI-11) BY p.e xnmm P—l..ft E:7. CBiw"f07I*I-_r , CODE/SEC. UFC Apendix iIFA UPC 903.2 FIRE DEPARTMENT P4XXEVIEWNUMBEN 04 17 '12 ��POLAEA COG SANTA CLARA COUNTY BUGGPEXMUNUMBER ATTACHMENT 5 14700 Winchester Blvd, Los Gatos, CA 95032-1818 (408) 3784010 • (408) 378-9342 (fax) • www.sccfdnrg CONnLOLNUMBEe FILE NUMBER 111-04-ZP-SD-GD DEVELOPMENT REVIEW COMMENTS SNEET BEWIREMEM Review of a proposed new 5,000 square foot single family residence with an attached garage. *** 7/23/2004 & 7/26/2004 Amended comments -See below *** of this Developmental proposal is limited to acceptability of site access and apply as they pertain to fire department operations, and shall not be ed as a substitute for formal plan review to determine compliance with I model codes. Prior to performing any work the applicant shall make ion to, and receive from, the Building Department all applicable ction permits. \ ad Fire Flow: The fire flow for this project is 2,000 gpm at 20 psi residual e. The required fire flow is not* available from area water mains and fire t(s) which are spaced at the required spacing. flow from area fire hydrants. Required Fire Flow Option (Single Family Dwellings): Provide an approved fire sprinkler system throughout all portions of the building, designed per National Fire Protection Association (NFPA) Standard #13D and local ordinances. The fire sprinkler system supply valving shall be installed per Fire Department Standard Detail & Specifications SP -6 (See attached). A State of California licensed fire protection contractor shall submit three (3) sets of plans, calculations, a completed permit application and appropriate fees to this department for review and approval prior to beginning their work. CXy, PLANS SPECS NEW FAUX AB DCCUPPXLY CONST. TYPE AWIIl &nM DATE PAGE LAH ❑ ❑ ❑ ❑ ❑ MIKE MA AIA 6/9/2004 1 OF 3 SEChLOOF MFA LDAO DESCNIPDON DY Residential Development Hokanson, Wayne NAME OF PROJECr LOCATION SFR- CHO 13389 Wildcrest Dr Organized as the Santa Clara County Central Fire Protection District Serving Santa Clam County and the communities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Caton, Monte sereno, Morgan Hill, and Saratoga FIRE DEPARTMENT SANTA CLARA COUNTY 14700 Winchester Blvd., Los Gatos, CA 95032-1818 (408) 378-4010 • (408) 378-9342 (fax) • MAuw.sccfd.org PLANREVIEWNUMBEB 04 1212 BIDOPEAMMMUMBER CONIIIOLMUMSEF FILEMUMSER 111-04-ZP-SD-GD DEVELOPMENT REVIEW COMMENTS :ODEASEC. SHEET NO. BEWIAEMENT L.2-.2 4 ...:.• C 1.4.4 �C 2.2.2 5 Premises Identification: Approved numbers or addresses shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Numbers shall contrast with their 6 7/23/2004 Amended Comments: Following a site inspection, the applicant is to be advised that this department considers the site to be inaccessible to fire apparatus due to existing topographical conditions. The improvement of the condition appears to be impractical. This condition is to be mitigated with the installation of certain access roadway improvement to be identified in comment #7 below. 7 A turnout shall be provided proximal to the new driveway leading to the residence. The dimension of the turnout shall be 55' in overall length with a cumulative roadway width of 20'(10' of existing pavement with 10' of additional width provided within the turnout area). The Civil Engineer shall refer to Standard, Detail and Specification D-1 of this department (see attached). The Civil Engineer shall submit plans to the Town of Los Altos Hills Building Department for and approval prior to commencing any construction. Ch, PLANS SPECS NEW NMOL AS OCCUPANCY CONST.TYPE AMiessaMln DATE PACE AH ❑ ❑ ❑ ❑ ❑ MIKE MA AIA - 6/9/2004 2 OF 3 2JFLOON NEA LoaD DESCHIPna. CY Residential Development Hokanson, Wayne TAME OF PROJECT - LOCATION SFR- CHO 13389 Wildcrest Dr Organized as the Santa Clara County Central Fire Protection District Serum, Santa Clam County and the cammunities of Campbell, Cupertino, Los Altos, Los Altos Hills, Los Gatos, Monte Serena, Morgan HiP, and Samtogo �P Ci�RA COG FIRE DEPARTMENT PUN REVIEW HUMBER 04 1272 4� SANTA CLARA COUNTY BLDG PERMRNUMBER 14700 Winchester Blvd., Los Gatos, CA 95032-1818 (408) 378-4010 • (408) 378-9342 (fax) • wuwsocid.org COMROLNUMBER — RLE NUMBER 111-04-ZP-SD-GD DEVELOPMENT REVIEW COMMENTS COOFISEG I SHEET I NO.I REQUIREMENT Received a faxed site plan revision from Mission Engineers depicting a fire department turnout at the location specified in the 7/23/2004 requirements. The reflected turnout and location of same will be by this department. Item #4 above is removed from conditions of Town of Los Altos Hills and applicant 7/27/2004. wh CFy PYN$ SPECS NEW IMIOL AS OCCL. TI TE .HEW AWIt—tMemF DAIS PAGE LAH ❑ E] ❑ ❑ ❑ MIKE MA AIA 6/9/2004 3 3 OF SELIFLOOR APo:A LOAD OESCPoPIIDN BY Residential Development Holcanson, Wayne NAME OF PROJECTIACRTION SFR- CHO 13389 Wildcrest Dr Organized as the Santa Clara County Central Fire Protection District Serving Santa Clam County and the communities of Campbell, CHpernino, Los Altos, Los Altos Bits, !os Gatos, Monte Sereno, Morgan Hill, and Saratoga COTTON, SHIRES & ASSOCIATES, INC. CONSULTING ENGINEERS AND GEOLOGISTS TO: Debbie Pedro Assistant Planner TOWN OF LOS ALTOS HILLS 26379 Fremont Road Los Altos Hills, California 94022 SUBJECT: Supplemental Geologic and Geotechnical Peer Review RE: Cho, New Residence File #111-04-ZP-SD-GD 13389 Wildcrest Drive ATTACHMENT & July 23, 2004 L0124A At your request, we have completed a supplemental geotechnical peer review of the application for site development using: Engineering Geologic Review (report) prepared by John Coyle & Associates, dated July 16, 2004; and Geotechnical Investigation, Proposed Two -Story Single -Family Structure (report), prepared by Wayne Ting and Associates, Inc., dated March 22, 2004. In addition, we have reviewed pertinent technical documents from our office files and discussed site conditions with the Project Geologist. DISCUSSION The applicant proposes to remove the existing residence and garage, and construct a new two-story residence and garage in approximately the same location. In our previous review report (dated June 16, 2004), we noted that the subject property appeared to be located in the upper scarp area of a previously unmapped landslide. We recommended that a Certified Engineering Geologist address potential risks to the proposed project resulting from landsliding, and estimate the depth of artificial fill materials present at the site. In addition, we recommended that Wayne Ting and Associates evaluate the results of the requested geologic evaluation, verify the adequacy of geotechnical design criteria to address existing site fill materials, and evaluate appropriate locations for water energy dissipaters (away from existing fill materials). CONCLUSIONS AND RECOMMENDED ACTION The Project Geologist has completed an evaluation of landslide hazards at the subject property. The consultant has concluded that the house site is not located on the Northern California Office Southern California Office 330 Village Lane 5245 Avenida Enemas • Suite A Los Gatos, CA 95030-7218 Carlsbad, CA 92008-4374 (408) 354-5542 • Fax (408)354-1852 (760) 931-2700 • Fax: (760) 931-1020 e-mail: losgatos®cottonshires.com www.cottonshires.com e-mail: cadsbad@cmtme,hires.com Debbie Pedro Page 2 July 23, 2004 L0124A failed mass of a previous landslide and that the overall landslide hazard at the site is low. The depth of existing fill materials in front of the existing house and upper portion of the driveway have been estimated to be approximately 8 feet thick Cracks in the driveway indicate that a portion of the fill may not be stable. The Project Geologist has recommended that Wayne Ting and Associates consider described fill conditions in project design. Submitted project documentation satisfactorily addresses our primary geotechnical project design concerns. We do not have geotechnical feasibility concerns with proposed site development and recommend geotechnical approval of the proposed layout of site improvements. We recommend that the following conditions be attached to the building permit application. Geotechnical Plan Review - The applicant's geotechnical consultant should evaluate the results of the project geologic report and verify that described site fill conditions are satisfactorily addressed by recommended project geotechnical design criteria. The consultant should review and approve all geotechnical aspects of the project building and grading plans (i.e., site preparation and grading, site drainage improvements and design parameters for foundations, retaining walls and driveway) to ensure that their recommendations have been property incorporated. The consultant should verify that appropriate locations have been selected for water energy dissipaters to minimize the potential for adverse slope stability impacts. The results of the plan review should be summarized by the geotechnical consultant in a letter and submitted to the Town Engineer for review and approval prior to issuance of building permits. 2. Geotechnical Field Inspection - The geotechnical consultant should inspect, test (as needed), and approve all geotechnical aspects of the project construction. The inspections should include, but not necessarily be limited to: site preparation and grading, site surface and subsurface drainage improvements, and excavations for foundations and retaining walls prior to the placement of steel and concrete. The results of these inspections and the as -built conditions of the project should be described by the geotechnical consultant in a letter and submitted to the Town Engineer for review prior to final (granting of occupancy) project approval. LIMITATIONS This review has been performed to provide technical advice to assist the Town in its discretionary permit decisions. Our services have been limited to review of the documents previously identified, and a visual review of the property. Our opinions and conclusions are made in accordance with generally accepted principles and practices of COTTON, SHIRES & ASSOCIATES, INC. Debbie Pedro Page 3 July 23, 2004 L0124A the geotechnical profession. This warranty is in lieu of all other warranties, either expressed or implied. POS:TS:rb Respectfully submitted, COTTON, SHIRES AND ASSOCIATES, INC. TOWN GEOTECHNICAL CONSULTANT Ted Sayre Su eMsmg Engineering Geologist Vtr175 ` ` Shim �� Principal Geotechnical Engineer GE 770 COTTON, SHIRES & ASSOCIATES, INC. Applicant's Name: Address: Reviewed by: � 40 . NEW 1�e-s . , ENVIRONMENTAL DESIGN COMMITTEE NEW RESIDENCE EVALUATION 7 7 ?1764 C Date: 5 i Existing Trees: (Comment on size, type, condition, location with respect to building site. Recommended protection during construction.) I Proposed Grading: (Impact on water table, nearby vegetation. Erosion potential. All grading at least 10' from property line?) Creeks and drainage: (Should a conservation easement be recommended? Sufficient space between house and conservation easement for circulation. Will construction impact wildlife migration (bridges, fences)? Is there a need for removal of invasive species?) Siting: (View impact: ridgeline, across valley, on neighbors. Will driveway impact neighbors' privacy (lights, noise)? Recommended mitigation (height, color, landscapb).) Other Comments: 4/%�.//A%1� �O