Loading...
HomeMy WebLinkAbout4.2ITEM 4.2 TOWN OF LOS ALTOS HILLS February 6, 2014 Staff Report to the Planning Commission SUBJECT: CONDITIONAL DEVELOPMENT PERMIT FOR A SWIMMING POOL AND SPA; LANDS OF SU; 25701 DEERFIELD DRIVE; FILE #301-13-ZP-SD-GD- CDP FROM: Nicole Horvitz, Assistant Planner 1 ;1/z APPROVED: Debbie Pedro, AICP, Community Development Director RECOMMENDATION: That the Planning Commission: Approve the requested Conditional Development Permit for a 504 square foot swimming pool subject to the recommended conditions in Attachment 1 and findings of approval in Attachment 2. BACKGROUND The subject property is a .381 acre parcel located on the north side of Deerfield Drive: On March 10, 2005, the Planning Commission approved a new 3,267 square foot two story residence with a 908 square foot basement and attached two car garage. In addition, a setback variance was approved to allow the two required uncovered parking spaces to be located within the east side yard setback. CODEREQUIREMENTS- As required by Section 10-1.1007 of the Zoning Ordinance, this application for a swimming pool has been forwarded to the . Planning Commission for review and approval. A Conditional Development Permit is required anytime a proposed project is located on a property with a lot unit factor (LUF) of 0.50 or less. Pursuant to Section 10-1.1007 (3) of the Zoning Ordinance, in reviewing a Conditional Development Permit application the Planning Commission determines whether the proposed development meets the standards of the Town by considering evidence in support of the findings of approval (Attachment 2). DISCUSSION Site Data: Gross Lot Area: .3 81 acres Net Lot Area: .3 81 acres Average Slope: 16.2% Lot Unit Factor: .330 Staff Report to the Planning Commission 25701 Deerfield Drive February 6, 2014 Page 2 of 7 Floor Area and Development Area: Area (sq. ft.) Maximum Existing Proposed Increase Remaining Development 5,850* 5,555 5,703 603 147 Floor 3,300 3,267 0 0 33 *Includes 500 sq. ft. development area bonus per Section 10-1.502.b.6 (Solar Ordinance) Site and Architecture The applicant is requesting approval of a Conditional Development Permit to construct a 504 square foot swimming pool and spa in the rear yard. The proposed pool and deck are in compliance with the setback and development area requirements established in Title 10, Zoning and Site Development of the LAHMC. The applicant is using the Council approved solar incentive to achieve the square footage to build the swimming pool on the property. Per Section 10-1.502 b.6 of the LAHMC, the 500 square feet of solar panels will need to be installed on the roof of the residence prior to final inspection of the swimming pool (condition of approval #5). The ordinance does not restrict CDP lots from utilizing the development area bonus. Outdoor Lighting No landscape lighting is proposed at this time except for lights located within the proposed pool. Trees & Landscaping One (1) pine tree is proposed to be removed with this application. Drainage Water runoff generated from the new development will be collected and routed into a detention vessel along the North East corner of the property. The vessel is. 18long with one (1) 2'6" diameter perforated pipe and percolates into the ground. Pursuant to Section 10-2.503, Drainage Facilities Standards, of the Municipal Code, the Engineering Department has reviewed and determined that the proposed drainage design complies with Town requirements. The Engineering Department will review and approve the final drainage plan prior to acceptance of plans for building plan check. Final "as -built" grading and drainage will be inspected by the Engineering Department, and any deficiencies will be required to be corrected prior to final inspection. Staff Report to the Planning Commission 25701 Deerfield Drive February 6, 2014 Page 3 of 7 Grading Total grading quantities include 70 cubic yards of export pool. The Engineering Department has reviewed the proposed grading and concluded that it is in conformance with the Town's grading policy. Neighbor Concerns To date, no correspondence has been received from the public. Committee Review The Environmental Design and Protection Committee commented that the proposed removal of the pine tree is acceptable (Attachment 3). CEQA STATUS The project is categorically exempt under CEQA per Sections 15303 (e). ATTACHMENTS 1. Recommended Conditions of Approval 2. Recommended Findings of Approval 3. Recommendations from Environmental Design and Protection Committee dated October 11, 2013 4. Worksheet #2 5. Development plans Staff Report to the Planning Commission 25701 Deerfield Drive February 6, 2014 Page 4 of 7 ATTACHMENT 1 ATTACHMENT 1 RECOMMENDED CONDITIONS FOR CONDITIONAL DEVELOPMENT PERMIT SWIMMING POOL LANDS OF SU; 25701 DEERFIELD DRIVE File # 301-13-ZP-SD-GD-CUP PLANNING DEPARTMENT: 1. No other modifications to the approved plans are allowed except as otherwise first reviewed and approved by the Planning Director or the Planning Commission, depending on the scope of the changes. 2. Prior to beginning any grading operation, all significant trees, particularly the heritage oak trees, are to be fenced at the drip line. The fencing shall be of a material and structure (chain- link) to clearly delineate the drip line. Town staff must inspect the fencing and the trees to be fenced prior to commencement of grading. The property owner. shall.. call for said inspection at least three days in advance of the inspection. The fencing must remain throughout the course of construction. No storage of equipment, vehicles or debris shall be allowed within the drip lines of these trees. Existing perimeter. plantings shall be fenced and retained throughout the entire construction period. 3. Prior to requesting the final inspection, a registered civil engineer or licensed land surveyor shall certify in writing and state -that "the location of the new pool and decking are no less than 30' from the side and rear property lines". The elevation of the new pool shall be similarly certified in writing to state that "the elevation of the new residence and cabana matches the elevation and location shown on the Site Development plan." The applicant shall submit the stamped and signed letter(s) to the Planning Department prior to requesting a final inspection. 4. All hardscape proposed to be removed as shown on the site plan (sheet L1.0 of the approved plans) shall be removed prior -to final inspection of the pool. 5. The 500 square feet of proposed photovoltaic solar panels shall be installed on the roof of the residence and finaled, prior to final inspection of the swimming pool. 6. Standard swimming pool conditions: a. Lights shall be designed so that the source is not visible from off-site. b. Drainage outfall structures shall be constructed and located to the satisfaction of the City Engineer. c. Pool equipment shall be enclosed on all four sides with.a roof for noise mitigation and screening. Staff Report to the Planning Commission 25701 Deerfield Drive February 6, 2014 Page 5 of 7 7. For swimming pools, at least one of the following safety features shall be installed to the satisfaction of the Town Building Official: a. The pool shall be isolated from access to the residence by an enclosure (fencing). b. The pool shall be equipped with an approved safety pool cover. c. The residence shall be equipped with exit alarms on those doors providing direct access to the pool. d. All doors providing direct access from the home to the swimming pool shall be equipped with a self-closing, self -latching device with a release mechanism placed no -lower than 54 inches above the floor. 8. Fences are approved as shown on the site plan. Any new fencing or gates shall require review and approval by the Planning Department prior to installation. 9. No new outdoor lighting is approved. There shall be one light per door or two for double doors. Light fixtures shall have frosted glass or be down lights. No lighting may be placed within setbacks except two entry or driveway lights. Any additional outdoor lighting shall be approved by the Planning Department prior to installation. ENGINEERING DEPARTMENT: 10. Peak discharge at 25701 Deerfield Drive, as a result of Site Development Permit 301-13, shall not exceed the existing pre -development peak discharge value of the property. Detention storage must be incorporated into the project to reduce the predicted peak discharge to the pre -development value. Provide the data and peak discharge hydrologic model(s) utilized, as well as, the calculations of the peak discharge value prior and post development. Determine the design peak runoff rate for a 10 -year return period storm and provide detention storage design plans to reduce the predicted peak discharge to the pre - development value. All documentation, calculations, and detention storage design (2 plan copies) shall be submitted for review and approval to the satisfaction of the City Engineer prior to acceptance ofplans for buildingplan check. 11. The Engineer of Record shall observe the installation of the drainage system, construction of the energy dissipaters, and completion of the grading activities and state that items have been installed and constructed per the approved plans. A stamped and signed letter shall be prepared and submitted to the Town prior to final inspection. 12. Any, and all, changes to the approved grading and drainage plan shall be submitted as revisions from the project engineer and shall first be approved by the Town Engineering Department. No grading shall take place during the grading moratorium (October 15 to April 15) except with prior approval from the City Engineer. No grading shall take place within ten feet of any property line except to allow for the construction of the driveway access. 13. Two copies of an erosion and sediment control plan shall be submitted for review and approval by the Engineering Department prior to acceptance of plans for building plan check. The contractor and the property owner shall comply with all appropriate requirements of the Town's NPDES permit relative to grading and erosion/sediment control. The first 100 Staff Report to the Planning Commission 25701 Deerfield Drive February 6, 2014 Page 6 of 7 feet of the driveway shall be rocked during construction and all cut and fill slopes shall be protected from erosion. All areas on, the site that have the native soil disturbed shall be protected for erosion control during the rainy season and shall be replanted prior to final inspection. 14. Two copies of a grading and construction operation plan shall be submitted by the property owner for review and approval by the City Engineer and Planning Director prior to acceptance of plans for building plan check. The grading/construction operation plan shall address truck traffic issues regarding dust, noise, and vehicular and pedestrian traffic safety on Deerfield Drive and surrounding roadways, storage of construction materials, placement of sanitary facilities, parking for construction vehicles, clean-up area, and parking for construction personnel: A debris box (trash dumpster) shall be placed on site for collection of construction debris. Arrangements must be made with the GreenWaste Recovery, Inc. for the debris box, since they have a franchise with the Town and no other hauler is allowed within the Town limits. 15. The property owner -shall inform the Town of any damage and shall repair any damage caused by the 'construction of the project to pathways, private driveways, and public and private roadways, prior to final inspection and release of occupancy permits. and shall provide the Town with photographs of the existing conditions of the roadways and pathways prior to acceptance of plans for building plan check. CONDITION .NUMBERS 10, 13, 14, and 15 SHALL BE COMPLETED AND SIGNED OFF BY THE ENGINEERING DEPARTMENT PRIOR TO ACCEPTANCE OF CONSTRUCTION PLANS FOR PLAN CHECK BY THE BUILDING DEPARTMENT. Project approval may be appealed if done so in writing within 22 days of the date of this notice. The building permit cannot be issued until the appeal period has lapsed. The applicant may submit construction plans to the Building Department after the appeal period provided the applicant has completed all conditions of approval required prior to acceptance of plans for building plan check. Upon completion of the construction, a final inspection shall be required to be set with the Planning and Engineering Departments two weeks prior to final building inspection approval. NOTE: The Site Development permit is valid for one year from the approval date (until February 6, 2015). All required building permits must be obtained within that year and work on items not requiring a building permit shall be commenced within one year and completed within two years. Staff Report to the Planning Commission 25701 Deerfield Drive February 6, 2014 Page 7 of 7 ATTACHMENT 2 ATTACHMENT 2 FINDINGS OF APPROVAL FOR A NEW SWIMMING POOL LANDS OF SU, 25701 DEERFIELD DRIVE File # 301-13-ZP-SD-GD-CDP 1. The site for the proposed development is adequate in size, shape and topography to accommodate the proposed intensity of development, including all structures, yards, open spaces, parking, landscaping, walls and fences, and such other features as may be required by this chapter. The proposed swimming pool on the .381 acre parcel. has been designed to fit within the development area, setbacks, and site topography. 2. The size and design of the proposed.structures create a proper balance, unity and harmonious appearance in relation to the size, shape and topography of the site and in relation to the surrounding neighborhood . The proposed pool is compliant with Town standards and is harmonious with the surrounding properties. 3: The rural character of the site has been preserved as much as feasible by minimizing vegetation and tree removal, excessive and unsightly grading and alteration of natural land forms. The existing trees and shrubs will be preserved as much as possible. One pine tree is proposed to be removed with the application. 4. The proposed development is in compliance with all regulations and policies set forth in the Site Development ordinance. The proposed residence is in compliance with all regulations andpolicies set forth in the Site Development Ordinance. N1 ATTACHMENT 3 E.ae SU � Chem ENVIRONMENTAL DESIGN and PROTECTION COMMITTEE Application forCha-...:. . _ .................... ri _..�. ..... __._ ......................... ._... ..__..._....._._............ Applicant Name: __.... D�s C`'p_.'�' _ _ �a. , - --------------- ........_. __.--.... _..._.._._-.__.._..___...._......................•__.-.__......._.__..---------------- . _..:............._._....._...._.____.. ....... _........._.. Applicant Address: Reviewed by: .......... _ _ ______........... _._.__.._.._.�_..._----.__-__--_-- ----__.......... COMMENTS Site impact - -- -------------- ---................ :...__ —_ _. _._ .... _._.. »..- -• -------- -.... ................ -.................. ... _........................ .-•-•-------•--...... _ Noise ....-..................... ................ ...._ -�_..._......�.-_.-_._.:.____-- _ __ _ _ --- -. _._.. - R: -------- --._.._-_._-.._--_........_.__._. __............ _._.._.... _......_.............. .. _.....__!!� _._...... ..i �..._ _ __ -••--- &iiks _............_............. _ _..._._..__..�.__•_-_---............. _.. Drainage _--....--_..._._..»_..__....».._._.._................... _...................... ..................... ................ .___.._........ _........... _...... ......"-- Easements ---..... -.......... -...... ............... _--..--------_...........-----.............._._.._...-----•--••-•-----»..- - - Existing Vegitation .._.... - ....... ......... ...... --- ------ ___ - . _........... _...._»._ ................................. .................... ..... --- - Mitigation_-_-_ _- - -................ ........... ... ...... ---.............. -....... -_.._....................... ..--•----------•-------•----------•----..»_...-----•-•-.... -....... 0 ATTACHMENT 4 TOWN OF LOS ALTOS HILLS PLANNING DEPARTMENT 26379 Fremont Road • Los Altos Hills, California 94022 • (650) 941-7322 • FAX (650) 94 1 -3) 160 WORKSHEET #2 EXISTING AND PROPOSED DEVELOPi41ENT AREA AND FLOOR ARCA • TURN IN WITH YOUR APPLICATION - 3ROPERTY OWNER'S NAME 'ROPERTY ADDRESS 25-1D l_.___. :ALCULA I`ED BY � �� DATE I L /,5 1. DEVELOPMENT AREA A. House and Garage (from part 2.r\) B. Decking C. Driveway and Parkina- D. Patios and Walkwaysy E. Tennis Court F. Pool and Pool Decking G. Accessory Building (from part 2.B) H. Solar Panels (ground mounted) 1. Any Other Coverage Tota[ Existing Proposed DA Credit Total U _..L_! --L SAI 2 (c9 —592, Roof Mounted. Solar Bonus (LAHMO Section 10-1.502) yes ; No Maximum Development Area -MDA (from worksheet #1) Maximum Development Area iv/ Solar Credit 2. FLOOR AREA A. HOUSE AND GARAGE a. First Floor b. Second Floor c. Attic d. Basement e. Garage f. Area over 17' B. ACCESSORY BUI1..DMOS a. First Floor b. Second Floor c. Attic Existing Proposed d. Basement Total Maximum Floor Area -MFA (from worksheet #1) SF 4SCO 5 14co 6,50 Total II TOWN IJSE ONLY CHECKED BY 1 DATE I�