My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3.3
LOSALTOSHILLS
>
Planning Commission
>
Planning Commission Packets
>
1998
>
January 14, 1998
>
3.3
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2016 12:02:31 PM
Creation date
12/7/2016 12:02:27 PM
Metadata
Fields
Template:
Staff Report
Date
1998-01-14
Item Number
3.3
Description
Site Development Permit for a New Residence, Second Unit, Pool House and Pool, and a Modification to the Tentative Map Conditions of Approval (Tract 7187); Lands of Rutner; 28500 Matadero Creek Lane; File #151-97-ZP-SD-GD-AMEND
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Planning Commission <br /> January 14, 1998 <br /> Lands of Rutner <br /> Page 3 <br /> residence from the lowest to highest point would be 28 feet, as the house is located in an <br /> area of approximately 20 percent slope and the roof line somewhat steps down with the <br /> slope. Story poles have been erected on the site outlining the new residence for the <br /> Commissioners' review. <br /> The exterior materials proposed for the residence are stucco with a concrete tile roof and <br /> led.gestone veneer accents. The residence would be visible from residences along Page <br /> Mill Road. The applicant has designed the residence lower on the hill and has designed <br /> the finished floor cut a maximum of 10 feet into the hill to lower the overall elevation of <br /> the new residence. In addition, there are a number of architectural features, including the <br /> varying rooflines, bay windows, second story balconies and the number of indented areas <br /> of the proposed new residence, which would help to reduce the appearance of bulk of the <br /> house. <br /> Second Unit <br /> The second unit is attached to the main house, at the southeast of the proposed garages, <br /> with its own entrance. The unit is proposed to be 418 square feet with an interior <br /> stairway to the basement. The unit would include a kitchen, living area and a complete <br /> bathroom. <br /> Pool House <br /> The pool house is proposed to be located at the same elevation as the pool. A retaining <br /> wall is designed into the rear of the building, as it is cut into the hill. The finished floor is <br /> proposed to be cut a maximum of 4 feet and the fill is limited to 2 feet, meeting the <br /> Town's grading policy. The maximum height of the building is 131/2 feet, and the <br /> roofline matches that of the main house. The unit includes a bar, living area and a <br /> complete bathroom. Condition #7 requires that the applicant file a deed restriction with <br /> the Town stating that the pool house will not be utilized as a second unit. <br /> Outdoor Lighting <br /> Two skylights are proposed along the rear roof of the new residence. Outdoor lighting <br /> has been shown on sheet 1 of the plans. Lighting appears to be minimal, with one light at <br /> each exit. Staff has included the standard condition (#10) for outdoor lighting, requiring <br /> that fixtures be downshielded and that all locations be approved by the Planning <br /> Department. <br /> Parking, Driveway, and Turnaround <br /> All of the four required parking spaces for the residence would be located within the <br /> garages with a fifth space for the second unit located to the east of the residence, along <br /> the driveway. The plans show that the garages are each 2 feet too narrow to meet the <br /> code requirement for a 2 car garage. Condition #1 requires that the garage spaces be <br /> reconfigured so that both garages have a minimum of 20 foot widths. Subsequently, the <br /> proposed development area would need to be increased by approximately 80 square feet. <br /> All of the required parking spaces are proposed out of the setbacks and have adequate <br /> backup area for the spaces.No retaining walls are proposed for the new driveway. <br /> Due to the long driveway proposed, the Fire Department has required a turnaround on <br /> site. The applicant has designed the turnaround to work with the required turnaround for <br />
The URL can be used to link to this page
Your browser does not support the video tag.